Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13635624
| No.13635624
- Product Categories
- Friendly Links
| Information Name: | Leakage Control and protective switching-type CPS KB02 Control and Protection |
| Published: | 2015-01-21 |
| Validity: | 365 |
| Specifications: | JKCPS-32 |
| Quantity: | 10000.00 |
| Price Description: | |
| Detailed Product Description: | CPS that "the control and protection of electrical switches" is a new type of low-voltage electrical products, is the latest development of our country to fill the gaps in the generation of product categories, as a new category of products, its product categories, code-named "CPS", English " Control and Protective witching Device "abbreviation, the products meet IEC60947-2 (1997)" Low-voltage switchgear and control equipment Part 6: Multiple function equipment Section 2: Control and protective switching devices "and GB14048.9-1998" low switchgear and control equipment multifunction devices (or equipment) Part 2: Control and protective switching devices (or equipment). " Function and use JKCPS (KB0) Control and protective switching devices using electromagnetic actuator to drive the movement to contact and breaking the circuit. All protective features and functionality through intelligent control unit and the current transformer sampling, after making logical operations and data processing, controlled release of the action, complete fault diagnosis and protection. Switch on a single low-voltage electrical implements circuit breakers, contactors, thermal relays and other low-voltage electrical functions in intelligent control have advanced level ranks. JKCPS (KB0) The main features are: in the form of intelligent product structure "from the match," the control and protection functions. The functional integration "circuit breaker (fuse) + contactor + thermal relay", it is possible to replace the traditional circuit breaker (fuse), contactors, overload (or over-voltage, phase) protection relays, isolators and other The traditional separation of electrical species. The separation of the control and protection devices on the main function of realization: off load current, short circuit protection, overload protection, undervoltage protection, emergency measures under state control, emergency stop and interlock. However, due to different manufacturers there are some differences in the electrical properties of the product market, as well as the choice of personnel and other reasons there are differences in the use of technical parameters, making complete sets of equipment consisting of unreasonable work endless reliable. In addition, the electrical device is composed by a separate control box, when you consider the needs of arcing distance and cooling, the cabinet itself nor can be made smaller. Multifunction Control and protective switching devices used, a significant reduction in the variety and number of lines required components for the design of low-voltage power distribution and control systems simplify provides an ideal foundation elements. But also greatly simplify circuit design, making electrical complete sets of equipment reliability, security greatly improved, but also makes the production, commissioning and routine maintenance in the future accordingly simple and easy. Especially after the adoption JKCPS, compact and flexible structure changed in the past had to adopt separate devices into a large box and stupid situation, especially for land-use tensions building electrical design, especially for embedded civil Concealed wall. In addition, from a comparative analysis of the technical and economic point of view, if the traditional "circuit breaker or fuse + contactor + thermal relay group" barricaded more control circuits, the price is not cheap, and easy enough due to careful selection of parameters and other causes composed of complete sets of equipment is not reasonable, not high reliability. Therefore, CPS products come out, will bring low-voltage electrical appliances to "integration" change the development of intelligent, has broad application prospects. The type and purpose of the main parameters of the main product type modules and accessories have a short-circuit protection (similar to the MCCB and fuse short-circuit protection), automatic control (similar to contact the remote control function), local operation and indication. The controller uses a microprocessor (MCU) digital display type setting, LED indication, but also has a residual current protection (leakage protection) function, you can select one of 30mA, 100mA, 200mA, 300mA, 500mA residual current protection level according to user needs ( When ordering please specify the value of the residual current in the back of the model). The controller turns on the motor or the distribution circuit signal sampling, calculation and analysis of embedded software by issuing the appropriate treatment instructions, control JKCPS off the main circuit and according to two sets of output contacts signal, according to the requirements of selection. Use is divided into a variety of types, types and specifications. Auxiliary contacts (mechanical passive F-type and L-type) with the main circuit contacts linked with electrical control and indication. Divided by the number of contacts on a variety of specifications. Provides eight pairs of auxiliary contacts simultaneously. Signal alarm contacts (mechanical passive) with F-type auxiliary contacts integrated with the operating mechanism linked with work status and cause of the malfunction indicator. With three pairs and two pairs of signals while providing any alarm contacts. Isolated auxiliary contacts (mechanical passive) and isolated operating mechanism linkage, to achieve control circuit or (and) auxiliary circuit isolation indicator that provides two pairs of auxiliary contacts simultaneously. Panel sets the operating mechanism mounted on the device panel, without opening to place on JKCPS operations, including turning, breaking, then buckle (reset). With a variety of different forms of mounting direction and specifications. The control circuit conversion module for AC-DC converter control circuit, low voltage control (such as a PLC direct control) function. Zero sequence transformer for detecting residual current in the primary circuit, the signal is transmitted to the controller. Time current characteristics JKCPS (KB0) series of control and protection switch main parameters JKCPS series normal operating conditions and installation conditions of the ambient air temperature: the lower limit of -5 ℃, the upper limit of not more than + 40 ℃, and the average temperature does not exceed 24h + 35 ℃; Installation site: altitude does not exceed 2000M; Humidity: the maximum temperature of + 40 ℃, the relative humidity of the air does not exceed 50%, at a lower temperature allows a higher relative humidity, such as in 20 ℃ up to 90%. For the condensation temperature to produce the occasional special measures should be taken; pollution: Environmental conditions for pollution degree 3; Installation category: Ⅲ class; the installation site without obvious shock and vibration and no rain and snow, the terminals of the power supply side, under Terminals for the load side, perpendicular to the ground installation is recommended. JKCPS-B Series Standard control and protection of electrical switches JKCPS-B standard model parameters using menu-driven display, parameter setting is simple, easy to grip often; and to select and adjust the basic parameters can be set or selected by the micro-switch on the control panel . Working conditions or failure corresponding LED displays (such as the control circuit voltage, over-current and over-under-under-voltage, etc.), enabling the user to know the first time what happened faulty equipment or line: You can also remotely by SCPS auxiliary contacts on (both passive) coupled with the corresponding external components can be opened or closed to adjust certain parameters of certain functions. Display and Key Description JKCPS (KB0) powered closing preceded in accordance with the control and protection of the load current of the long delay line and the short time delay setting current is set at a desired value. After power-lit digital display auxiliary voltage and current monitoring cycle to the A, B, C three-phase circuit operating current value. Set key: when there is no load operation, press this key to enter the parameter setting mode data key: The flashing word bit modification in steps of 1 (0-9 cycles) Shift key: select words set the set state position, the selected word bit is flashing reset button: After parameter setting is complete, press to save the parameters and put into normal operation state run operation JKCPS monitor access to work after the power button, LED displays the voltage value, can double as a voltmeter, after three bit display voltage. JKCPS at runtime ammeter function can double the operation of three-phase current cycle press "shift key" can be directed to display the A-phase, B phase, C, L (leakage) current operation press the "reset button" to restore the three-phase cycle Current operation of fault-finding: no-load operation JKCPS, press the "data keys", and the control panel fault type symbol, you can view the first three fault types; display to indicate voltage value out of the fault finding, a normal operating status monitoring; or restart JKCPS exit fault finding. Protection parameters provided in the motor up and running, do not press the Set button, so as not to chip program error or failure; no-load operation; press "Settings button" Select setting type, followed by "shift key", select the data shift, press "Data key" data modifications; a parameter setting is completed, press the "set key" to enter the next set state until the beam knot; without the option should be set to give up, after all parameters are set, press the reset button to exit set state, shows the voltage value. Panel buttons and display the contents of the order of operations JKCPS-B overall and mounting dimensions JKCPS-F Series fire control and protection of electrical switches JKCPS-F Fire-related products through national scientific and technological achievements and acceptance. Expert opinion that the product is a set of isolators, circuit breakers (fuse), contactors, protection relays and other multifunctional Fire-type electrical appliances, and has a remote and local control panel instructions; its maximum rated current of 125A, limit When breaking capacity up to 80kA, realize the fire system overload, overcurrent "alarm only, without tripping" and short "Alarm + Trip 'specific requirements, product technology is the leading domestic level. Dimensions same basic type. JKCPS-G series of isolated control and protective switch in the handle of the standard control and protective switch increases the padlock, users with in the course of the corresponding fixed padlock to handle, suitable for distribution circuits and motor circuits power supply isolation, can meet the requirements of the main circuit isolation, but also to meet the requirements of the control loop isolation, and clearly shows its status by switching position indicator (operating knob). Once isolated control and protection switch lock, only qualified persons to operate the switch, this switch also has isolated defenses "do not move" function. Dimensions same basic type. JKCPS-L series leakage control and protective switching electrical characteristics based on the basic type control and protection switch on the increase in leakage protection, to prevent electric shock injury accident, avoid fire accidents caused by leakage, protect the personal safety and security equipment . Its auxiliary switch fitted leakage test button, the user can be every 1-2 months you press a button to test the leakage function is normal. Rated residual current protection characteristics of the rated residual current I △ n size according to customer requirements set. Equipment used to detect ground fault current, can provide additional protection against damage due to aging equipment insulation and fire due to overcurrent protection can not detect the continuity of the ground fault current and other hazards. Test button is used to check the residual current trip function is not designed to perform the opening operation. Residual current protection parameters as shown below JKCPS-S3 series dual power automatic transfer switch JKCPS-S3 series dual power automatic transfer switch is JKCPS (KB0) main switch, accessory combination with digital voltage controllers, mechanical and electrical chain chain, which form dual power automatic transfer switch. JKCPS-S3 series dual power automatic transfer switch is mainly used for AC rated frequency 50Hz / 60Hz, rated voltage up to 415V, rated current up to 125A of two-way power supply system, when JKCPS-S3 is in automatic mode, commonly found in the power phase, over voltage, under voltage fault, JKCPS-S3 automatically switch to standby power to ensure the reliability and security of supply, JKCPS-S3 is suitable for emergency power during a power switch to stop the load. According to customer needs with optional load various protection functions, current, phase, short circuit, undercurrent, which form PC level and CB-level dual power automatic transfer switch, dual power automatic or manual control and protection. CB current level products to access, load and breaking under normal conditions include the requirement under current overload conditions, and the ability to access, carrying a certain time and breaking under the abnormal conditions (such as short circuit current). JKCPS-S3 series dual power automatic transfer switch selectable power grid and grid generator mode, and can provide a feedback signal (taken from JKCPS (KB0) auxiliary contact signal), and has three work stations, integrated, The modular, small size, beautiful appearance, with 0.1 ~ 125A specifications, configuration flexibility, ease of operation, flexible installation angle, high degree of protection. Product complies with IEC60947-6-1 standard GB14048.11 and product features have three type, that is commonly used power pass, pass and dual standby power points (off) position; with momentary and delayed-type; action time: Momentary Conversion time of less than 80 ms; the total operating time-delay within 2 to 32 seconds adjustable; integrated, modular, small size, beautiful appearance, with 0.1 to 125 amps of current specifications, configuration flexibility, ease of operation, flexible installation angle high degree of protection; available in 3 or 4-pole (4P or 3P + N); Utilization category: AC-33B, motor load or include motors, resistive load and mixed load of 30% or less of incandescent loads; perfect protection, control reliable signal range, remote control, flexible combinations. JKCPS-S3 overall and mounting dimensions |
Admin>>>
You are the 7206 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Electric Co., nine open All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7206 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Electric Co., nine open All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

